Sale!

Gensave-CS-SVG050

270,000.00

Discover unparalleled power efficiency with Gensave’s SVG Series. This innovative solution redefines energy distribution by seamlessly correcting power factors and compensating for harmonics. Powered by intelligent IGBT technology, it ensures stable real-time correction without traditional constraints. Experience dynamic efficiency as the SVG swiftly adapts to changing reactive power demands, providing precise and reliable compensation in just 3/4 of a cycle. Choose Gensave’s SVG Series for a cutting-edge power solution that transcends expectations, delivering a new era of energy optimization.

Category: Tag:

Description

Discover the Future of Power Optimization with Gensave’s SVG Series!
🚀 Revolutionize Your Power Distribution:
Unlock unparalleled power factor correction and harmonic current compensation with Gensave’s cutting-edge SVG Series. Designed with precision and innovation, this SVG transforms the way you manage power efficiency.
🌐 Intelligent Power Correction:
Immerse yourself in a world where the Gensave SVG takes charge, seamlessly aligning current and voltage phase angles on the transformer side. Detecting inductive or capacitive currents, our SVG effortlessly generates leading or lagging currents into the grid, achieving a harmonious synchronization that transforms your power distribution system.
⚡ Beyond Conventional Solutions:
But that’s not all – the Gensave SVG Series goes beyond ordinary solutions. Correct load imbalances and enjoy the added benefits of partial compensation for harmonic currents. Trust in Gensave’s commitment to innovation and efficiency as we redefine the standards of power quality.
🌟 Intelligent Technology at Its Best:
Experience the future with Gensave’s SVG, an entirely new approach to power factor correction. Utilizing intelligence-based IGBT technology with excellent switching, our SVG provides stable, accurate real-time power factor correction without the drawbacks of traditional methods.
🔄 Dynamic Step-Less Compensation:
Say goodbye to the limitations of capacitor-based systems. The SVG’s high-speed two-level inverter reacts swiftly to changes in reactive power, ensuring full correction in just 3/4 of a cycle. Enjoy dynamic step-less compensation that is precise, accurate, fast, and durable.
⚙️ Resonance-Free and Reliable:
With Gensave’s SVG, there’s no chance of system resonance, and even under low voltage conditions, it provides full reactive power compensation. Plus, being a completely inverter-based solution means no AC Capacitors to fail, ensuring reliability for the long run.
Choose the future of power efficiency – choose Gensave’s SVG Series. Elevate your power distribution capabilities with intelligence-based technology and dynamic compensation. Say hello to a new era of precision and reliability in power correction!

Technical data and specifications
Rated Voltage 400V

20%~+20%

30、50、75、100

Grid voltage range
Individual module capacity(kVar)
Frequency Overall efficiency 50/60Hz(-10%~+10%)
>97%
 

CT configuration

Closed or open loop (Open loop is recommended incase of parallel

operation)

Overall response time <7.8ms
Grid type 3P3W,3P4W
Overload capacity 110%-Continuous operation,120%-1min
Circuit topology 3-level topology
Switching frequency 20kHz
Modularity Maximum 20 units can be combined
Redundancy Master/master or master/slave arrangement
Typical power losses <2.5%(depending of the load)
Target power factor Adjust able from–1to1
Harmonic compensation Available
Unbalance compensation Available
Display 1.8/4.3/7-inchHMI(Optional)
Communication ports RS485Modbus(RTU)
Noise level <69dB(depending on the load and model)
Altitude De rating usage>2000m
Ambient temperature Operating Temperature:-35°C~55°C,Derating usage above55℃
 

Humidity

Storage temperature:-45°C~70°C
5%~95%RH,non-condensing
Protection class IP20
Design/Approvals EN62477-1(2012),EN61439-1(2011)
EMC EN/IEC61000-6-4,ClassA
Certification CE,CQC