Smart Controller (LCD Display) Gensave PRV-Z Series

9,374.00

PRV-Z series is an integrated controller for reactive power compensation and distribution monitoring, which integrates data acquisition, communication, reactive power compensation, power grid parameter measurement, analysis and other functions. If RS485 communication mode (JK-GHY-Z) is adopted for this product, upto 32 sets of HY series combined low-voltage power capacitor can be connected to the net work. Or choose 12V voltage output control mode (PRVD)-, which can provide 12 steps and 16 steps control output (only one of the two modes can be selected)

Description

Precautions before use

This manual is only for the personnel responsible for installation, maintenance and operation.

  1. The sampling voltage corresponds to the sampling current one by one, and the phases equence is the same.
  2. The distribution sampling current terminals IA+, IA-, IB+, IB-, IC+,IC -must correspond to S1andS2 of phase A, Band C primary current transformers one by one.
  3. For example, if the ratio is 500:5,it is set to 100.
  4. Correctly set  the compensation current ratio of the primary current transformer in the compensation cabinet, for example,500:5,then set it to 100.
  5. (only JK-GHY-D type, i.e. matching with composite switch)

For example, if the first output node corresponds to the three phase compensation type of 30kvar,itisset to 1  G-B 30kvar.

For example, if the second out put no de corresponds to the phase A of the split phase compensation type(0.25-15-3YN),itissetas2F-A5kvar.

Intelligent low voltage reactive power compensation measurement and control device.

Overview

PRV-Z series is an integrated controller for reactive power compensation and distribution monitoring, which integrates data acquisition, communication, reactive power compensation, power grid parameter measurement, analysis and other functions. If RS485 communication mode (JK-GHY-Z) is adopted for this product, upto 32 sets of HY series combined low-voltage power capacitor can be connected to the net work. Or choose 12V voltage output control mode (PRVD)-, which can provide 12 steps and 16 steps control output (only one of the two modes can be selected)

  normal working conditions, installation conditions and precautions

  1. Ambient temperature:-25℃~55℃                 Altitude: ≤2000 m
  2. Relativehumidity:20%~90%at40 ℃
  3. other requirements :no flammable and explosive medium, conductive dust and corrosive gases.

   main technical parameters

  1. Rated working voltage:220 V±20%, frequency:50Hz;
  2. Power consumption:≤10va.
  3. Analog quantity of sampling current:≤5a,50Hz;
  4. Input impedance of current analog quantity: ≤0.1Ω;
  5. Sensitivity≤200mA;
  6. The operation error is less than ±0%andthe clock error is less than 1s/ d;
  7. Measurement accuracy: voltage,current,powerfactor1.0level,reactive power, active power ac-curacy higher  than 2.0level.
  8. PRV-Z:RS485 communication controls 32intelligent capacitors or 16communication type composite switches;

  main features

  1. It has LCD English display function and man-machine interface, which is convenient for measure-ment parameter display, control parameter setting and record query.
  2. It has the functions of voltmeter, ammeter, power factor meter, capacitor switching status indicator (including three-phase voltage, current, power factor, reactive power, active power, voltage harmon ic, current harmonic and zero sequence current measurement, capacitor switching status indication and alarm in formation).
  3. It as the functions of manual switching and automatic control.
  4. It has the function of running parameter setting and query.5,12,16 steps active output or RS485 communication control.

6,with standard RS-485b us cascaded with other devices to achieve remote control, data reading, parameter setting and other functions.

7.It has the function of on-line monitoring of reactive compensation capacitor state(this function module needs to be customized).

8,withUSB interface, can download U disk, convenient for local data transcription.(this function

module needs to be customized).

  1. It has the function of historical data storage and Statistics (including switching records, maximum value records, event records, alarm records, segmented power factor statistics, parameters before and after compensation, maximum and minimum load values, maximum and minimum compensation values). It can store the operation data list and 255 switching records and operation event records in the last half year.(this function module needs to be customized).
  2. Can provide alarm passive out put function(this function module needs to be customized)